OVERVIEW
POLYCOM OBi302 IGNITION PROCESS
The following is for ignition of the Polycom OBi302 ATA adaptors where the version is 3.2.X onwards. From these version onwards access to the GUI via the internet (WAN) port is off by default. Connection via GUI can be made to the device is via the LAN port using direct connection.
The LAN port will distribute a DHCP address to your PC for direct connection. Default IP address of the OBi302 LAN is 192.168.10.1
LAN PORT ACCESS & ADDRESSING:
The LAN port of the OBi302 is 192.168.10.1 by default. Connection of a LAN cable from this port on the OBi302 direct to your PC will allow GUI access. Enter this address into a web browser for access.
INITIAL LOGIN CREDENTIALS
Default parameters can be used to login to the OBi GUI interface, there are 2 levels from default admin and user
DEFAULT CREDENTIALS
USERNAME PASSWORD |
admin | admin |
user | user |
For security on initial login you will be prompted to update the password.
Please ensure the password is safe. The device will be accessible from the internet
PASSWORD UPDATING
OBi Menu Tree Item: System Management
The passwords can be updated in System Management -> Device Admin
Changing passwords add additional security to the device. We suggest changing both the ADMIN and USER accounts.
CONFIGURATION OPTIONS |
AdminPassword | Untick Default and change password in the Value column |
UserPassword | Untick Default and change password in the VALUE column |
FIRMWARE
OBI Menu Tree Item: System Management
Ensure the Obihai firmware is upgraded to the newest version available. See the currently recommended firmware link below.
Once downloaded you can complete the upgrade via the System Management -> Firmware Update menu:
)
GUI ACCESS VIA INTERNET PORT (WAN):
OBi Menu Tree Item: System Management
For registration of service the INTERNET port must be connected. This port will obtain a DHCP address.
Connecting the OBI302's INTERNET to the local network switch, the administration web pages (GUI) login is disabled by default. For access to the GUI via the INTERNET (WAN) port, you are required to enable the feature Access from WAN. This is located within the System Management -> Device Admin
Note: Service Web page admin from the lan side is always allowed and cannot be disabled
CONFIGURATION OPTIONS
|
AccessFromWAN | Untick Default and Enable by Checking the box in Value column
|
|
|
Enabling this option will allow access from the internet, Ensure the login password is secure
On completion of ignition of the Polycom OBi302 the following KB article can assist in the configuration of your requirements:
POLYCOM OBi302 REGISTRATION TO CHANNEL UC - SIP TRUNK:
Configuring the OBi302 for direct SIP trunks from ChannelUC to use for PSTN line emulation of trunks for legacy phone systems or direct fax line terminals, supporting information can be found within the following KB article: Polycom OBi302 Registration to Channel UC SIP Trunk - (Fax Connection)
Configuring the OBi302 for direct SIP extension to emulate an analogue extension of the EclipseUC platform for analogue devices (single line devices), e.g. Fax extensions, tone ringers, analogue cordless devices, supporting information can be found within the following KB article: Polycom OBi302 Registration to EclipseUC platform - SIP Extension